聯(lián)系電話:
15821734033
您現(xiàn)在的位置:首頁 > 產(chǎn)品展示 > 常規(guī)ELISA試劑盒 > 人激素ELISA試劑盒 > BioSwamp人抑制素B(INH-B)ELISA試劑盒(貨號(hào):HM10649)
BioSwamp人抑制素B(INH-B)ELISA試劑盒(貨號(hào):HM10649)
產(chǎn)品名稱:人抑制素B(INH-B)ELISA試劑盒
英文名稱:Human Inhibin B (INHB) ELISA Kit
品牌:BioSwamp
貨號(hào):HM10649
規(guī)格:96T
有效期:Six months
保存溫度:2-8℃.
For the quantitative in vitro determination of INHB concentrations in Human culture supernates, serum, plasma and tissue.
INTENDED USE
An enzyme immunoassay quantitative measurement in cell culture in vitro Human INHB supernates, serum, plasma and tissue.
PRINCIPLE
The kit assay Human INHB level in the sample,use Purified Human INHB antibody to coat microtiter plate wells, make solid-phase antibody, then add INHB to wells, Combined INHB antibody which With HRP labeled , become antibody - antigen - enzyme- antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of INHB in the samples is then determined by comparing the O.D. of the samples to the standard curve.
WARNINGS AND PRECAUTIONS
l This kit is only for scientific research, and shall not be used as a clinical diagnosis of use.
l Before starting the assay, read the instructions compley and carefully. Use the valid version of the package insert provided with the kit. Be sure that everything is understood.
l The microplate contains snap-off strips. Unused wells must be stored at 2 °C to 8 °C in the sealed foil pouch and used in the frame provided.
l Pipetting of samples and reagents must be done as quickly as possible and in the same sequence for each step.
l Use reservoirs only for single reagents. This especially applies to the substrate reservoirs. Using a reservoir for dispensing a substrate solution that had previously been used for the conjugate solution may turn solution colored. Do not pour reagents back into vials as reagent contamination may occur.
l Mix the contents of the microplate wells thoroughly to ensure good test results. Do not reuse microwells.
l Do not let wells dry during assay; add reagents immediay after completing the rinsing steps.
l Allow the reagents to reach room temperature (21-26°C) before starting the test. Temperature will affect the absorbance readings of the assay. However, values for the patient samples will not be affected.
l Never pipet by mouth and avoid contact of reagents and specimens with skin and mucous membranes.
l Do not smoke, eat, drink or apply cosmetics in areas where specimens or kit reagents are handled.
l Wear disposable latex gloves when handling specimens and reagents. Microbial contamination of reagents or specimens may give false results.
l Handling should be done in accordance with the procedures defined by an appropriate national biohazard safety guideline or regulation.
l Do not use reagents beyond expiry date as shown on the kit labels.
l All indicated volumes have to be performed according to the protocol. Optimal test results are only obtained when using calibrated pipettes and microtiterplate readers.
l Do not mix or use components from kits with different lot numbers. It is advised not to exchange wells of different plates even of the same lot. The kits may have been shipped or stored under different conditions and the binding characteristics of the plates may result slightly different.
l Avoid contact with Stop Solution containing 0.5 M H2SO4. It may cause skin irritation and burns.
l Some reagents contain Proclin, BND and/or MIT as preservatives. In case of contact with eyes or skin, flush immediay with water.
l TMB substrate has an irritant effect on skin and mucosa. In case of possible contact, wash eyes with an abundant volume of water and skin with soap and abundant water.
l Chemicals and prepared or used reagents have to be treated as hazardous waste according to the national biohazard safety guideline or regulation.
l For information on hazardous substances included in the kit please refer to Material Safety Data Sheets
MATERIALS PROVIDED WITH THE KIT
1. Instruction 1
2. Closure Plate Membrane 2
3. Microelisa Stripplate 12well×8strips
4. Standard 2560pg/ml 0.6ml×1 bottle
5. Standard diluent 2ml×1 bottle
6. Biotinylated anti –INHB–antibody 1.5ml×1 bottle
7. Chromogen Solution A 6ml×1 bottle
8. Chromogen Solution B 6ml×1 bottle
9. Stop Solution 6ml×1 bottle
10.HRP-Conjugate Reagent 6ml×1 bottle
11.Wash Buffer Concentrate (20ml×30 fold)×1bottle
MATERIALS REQUIRED BUT NOT PROVIDED
l Microplate reader capable of measuring absorbance at 450 nm.
l Precision pipettes to deliver 2 ml to 1 ml volumes.
l 100 ml and 1 liter graduated cylinders.
l Calibrated adjustable precision pipettes, preferably with disposable plastic tips. (A manifold multi-channel pipette is desirable for large assays.)
l Absorbent paper.
l 37°C incubator.
l Distilled or deionized water.
l Data analysis and graphing software. Graph paper: linear (Cartesian),log-log or semi-log, or log-logit as desired.
l Tubes to prepare standard or sample dilutions.
STORAGE CONDITIONS
u When stored at 2 °C to 8 °C unopened reagents will retain reactivity until expiration date.
u Do not use reagents beyond this date. Opened reagents must be stored at 2 °C to 8 °C.
u Microtiter wells must be stored at 2 °C to 8 °C. Once the foil bag has been opened, care should be taken to close it tightly again.
u Opened kits retain activity for 8 weeks if stored as described above.
REAGENT PREPARATION
Bring all reagents to room temperature before use
SPECIMEN COLLECTION AND PREPARATION
1. Serum-Use a serum separator tube(SST) and allow samples to clot for 30minutes before centrifugation for 15minutes at approximay 1000 xg.Remove serum and assay immediay or aliquot and store samples at
2. Plasma-Collect plasma using EDTA or Citric acid sodium as an anticoagulant.Centrifuge samples for 15 minutes at 1000 x g at 2
3. Cell culture fluid and other biological fluids-Remove particulates by centrifugation and assay immediay or aliquot and store samples at
ASSAY PROCEDURE
u General Remarks
l All reagents and specimens must be allowed to come to room temperature before use. All reagents must be mixed without foaming.
l Once the test has been started, all steps should be completed without interruption.
l Use new disposal plastic pipette tips for each standard, control or sample in order to avoid cross contamination.
l Absorbance is a function of the incubation time and temperature. Before starting the assay, it is recommended that all reagents are ready, caps removed, all needed wells secured in holder, etc. This will ensure equal elapsed time for each pipetting step without interruption.
l As a general rule the enzymatic reaction is linearly proportional to time and temperature.
l Determine absorption with an ELISA reader at 450 nm against 630 nm as reference. If no reference wavelength is available, read only at 450nm. If the extinction of the highest standard exceeds the measurement range of the photometer, absorption must be measured immediay at 450 nm against 630 nm as reference.
u Assay Procedure
1. Dilute standard: Prepare sixs test tube ,make number successively,add Standard diluent 100ul to ervery test tube,add Original density Standard 100ul to the first test tube, Gently mix;then take out 100ul from the first test tube and add to the second test tube, Gently mix; then take out 100ul from the second test tube and add to the third test tube, Gently mix; then take out 100ul from the third test tube and add to the forth test tube, Gently mix; then take out 100ul from the forth test tube and add to the fifth test tube, Gently mix; take out 100ul from the fifth test tube and Discard,make the sixth test tube as standard 0. the density Standard of every test tube is :1280pg/ml,640 pg/ml,320 pg/ml,160 pg/ml ,80 pg/ml,0 pg/ml.
set Standard wells on the Microelisa Stripplate , add different concentrations of standard 50 ul successively .
2. Add samples: Set blank wells separay (blank comparison wells don’t add samples ,Biotinylated anti –INHB -antibody and HRP-Conjugate reagent), testing sample wells. add Sample 40μl to testing sample well, then add Biotinylated anti –INHB-antibody 10μl , don’t touch the well wall as far as possible, and Gently mix.
3. Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at
4. Configurate liquid: 30-fold Wash Buffer Concentrate diluted 30-fold with distilled water and reserve.
5. washing:Uncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.
6. add enzyme:Add HRP-Conjugate Reagent 50μl to each well, except the blank well.
7. incubate:Operation with 3.
8. washing:Operation with 5.
9. color:add Chromogen Solution A 50μl and Chromogen Solution B 50μl to each well. Gently mix, incubate for 15 min at
10. Stop the reaction:Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color Immediay).
11. assay:take blank well as zero , measure the optical densit (OD) at 450 nm after Adding Stop Solution and within 15min.
CALCULATION OF RESULTS
l Calculate the average absorbance values for each set of standards, controls and patient samples.
l Construct a standard curve by plotting the mean absorbance obtained from each standard against its.
l Concentration with absorbance value on the vertical(Y) axis and concentration on the horizontal (X) axis.
l Using the mean absorbance value for each sample determine the corresponding concentration from the standard curve.
l Automated method: The results in the IFU have been calculated automatically using a 4 PL.
l (4 Parameter Logistics) curve fit. 4 Parameter Logistics is the preferred calculation method. Other data.
l Reduction functions may give slightly different results.
l The concentration of the samples can be read directly from this standard curve. Samples with.
l Concentrations higher than that of the highest standard have to be further diluted. For the calculation of.
l The concentrations this dilution factor has to be taken into account.
技術(shù)支持:化工儀器網(wǎng) 管理登陸 網(wǎng)站地圖